DSC Alarm Cannot Communicate With DLS Software

DSC Alarm Cannot Communicate With DLS Software

First please triple check that the PCLINK serial board is plugged in correctly as it is possible to insert it incorrectly or off by a pin.

Generally speaking the issue here is that the customer/installer is using a DSC serial interface while today's computers use USB only - therefor a USB to Serial adapter is used.  Sadly they are not all created equal and some will work, while others will not.

We have found the Keyspan USA-19HS to be most compatible.

Make sure you set the DLS software to communicate on the correct COM port!

Also you will need to activate the connection through the keypad. Entering programming section 499 then installer code and 499 again.

    • Related Articles

    • DSC DLS Programming Software

      DSC's DLS downloading & programming software allows local and remote programming of DSC PowerSeries and Neo security systems using Windows software. For professional installers please register with DSC to access DLS sofware and materials: ...
    • EVL4 Universal Monitoring and Control of DSC Neo and Other Security Alarm Systems

      Since DSC Powerseries was discontinued and replaced by Neo alarm system panels, we have been asked if the EVL4 card is compatible for self monitoring or pro monitoring through the EyezOn or Connect2Go service and apps. As of writing the EVL4 is not ...
    • UNO Hybrid Alarm FAQ

      UNO Hybrid Alarm FAQ from our recent UNO launch webinar Q: Can we expect the UNO panel to be seen exactly as if it was an Envisalink 4, so that HomeAutomation integrators can use the same drivers in their Home Automation platforms? A: UNO shares the ...
    • Connect 120V wired smoke detectors to security alarm system like DSC, Vista, Concord

      We are often asked how to add 120V wired smoke detectors to a low voltage security alarm system like DSC, Vista, Concord or Elk. First we need to point out that smoke detectors are a life safety product and so it's critical that you read and ...
    • DSC Alarm Without Telephone Connection

      If you will not be connecting your DSC alarm system to a telephone line, you need to ensure that it understands this, since by default it expects a phone condition and will give a trouble warning if the panel is not connected to a working phone line. ...