Enrolling DSC Wireless Sensors on RFK5500
Note: Default installer code is 5555
1. Enter [ ✱ ][8][Installer Code][898]. The LCD displays the following: “Wireless Enrollment Mode.”
2. Place the wireless device in the desired location.
3. Activate the device as described in the associated installation sheet. The electronic serial number (ESN) is displayed.
4. Press [ ✱ ] to confirm the ESN. If the serial number is incorrect, press [#] to discard it, and repeat this step. After successful confirmation of
the serial number, the system prompts for the zone number. The next available zone is displayed.
5. Enter a zone number (01-64) then press [ ✱ ] to accept. The next available zone is preloaded.
NOTE: Only one device may be enrolled in each zone. If a zone already has a device enrolled, press [*] to overwrite the zone or [#] to enter
another zone number.
6. After successful entry of the zone number, the system prompts for the zone type. (The recommended zone type is displayed). Press [ ✱ ] to
accept the zone type or enter:
Device Type Zone Definition
2 Door/Window Contact [01] Delay 1
3 PIR or Glassbreak [05] Interior, Stay-Away
4 Smoke Detector [88] Standard 24 Hr Fire (Wireless)
5 Pendant [16] 24 Hour Panic
8 CO Detector [81] 24 Hour CO Detection
Related Articles
Enrolling Wireless Sensors on DSC Systems Using RFK5501 Keypad
How to enroll wireless devices into a DSC alarm system using a PK5501 or RFK5501 keypad by manually entering the device ESN. Enter [ ✱ ][8][Installer Code][804]. 01 for Zone 1 02 Zone 2 and so on Enter in 6 digit ESN number then hit # twice Enter ...
Enrolling Wireless Key Fobs To DSC RFK5500/RFK5501 Keypads
Wireless keyfobs need to be enrolled in slots 41 through 56 with the first key in 41, second key in 42, etc. So to register the first key fob: *8 Installer's Code 804 41 XXXXXX (the Electronic Serial Number of fob #1) ## If the fob does not ...
Adding Wireless to the E27 and When to Use the Bus Versions of the Wireless Cards
The AERF3 or AERF9 add wireless to the Elk Alarm Engine E27 panel. These wireless cards are available as bare cards that connect to the panel. Or as a bundle with a bus adapter. The Elk E27 Alarm Engine main panel can accept one RF Receiver directly, ...
Wireless PIR Motion Detector Testing and Operation
Wireless motion sensors from DSC, Elk, Honeywell, Resolution, etc are designed to trip once when they see motion and then go to 'sleep' for quite a while before waking up to detect motion again. This is to conserve battery. They also don't flash ...
Wireless PIR Motion Detector Testing and Operation
Wireless motion sensors from DSC, Elk, Honeywell, Resolution, etc are designed to trip once when they see motion and then go to 'sleep' for quite a while before waking up to detect motion again. This is to conserve battery. They also don't flash ...