Ensure that phone line is connected to the larger jack on back of the Simon XT
Ensure that the phone service type is not VOIP, which may not be compatible with the Simon XT dialer
Enter in the appropriate telephone number(s) to call including area code and 1 in front as appropriate
Set reporting format to VOICE DIAER under reporting>report->Communication Modes>
Ensure that the dialer delay>phone options>system programming is set to 30 seconds.
If you have any outstanding conditions you may need to clear the status
To clear system status, press the STATUS button, read and/or listen to the status messages, then press
DISARM. If the trouble condition was a low system battery, perform a sensor test. The STATUS light
should turn off if all trouble conditions have been corrected.
Related Articles
GE Interlogix Simon XT V2 Installer and User Manual
Simon XT Installation and Programming manual, and user manuals. For V2 versions of panel shipping since Sept 2010
Adding a wired siren to Simon XT and Xti
To use a wired siren with a Simon XT or XTi system: Negative wire from the siren to the HW1- on the panel. Positive wire to the + HW 1&2 DC out. You will also need to program the panel to tell it you have a siren tied in to the panel: Go to ...
DSC Powerseries/Alexor Residential Dial (Self Monitoring) Programming
If you wish to have your DSC Alexor alarm system use residential dial (self monitoring) be sure to set the following sections appropriately: Some of these are already defaulted that way but better to check them to ensure they have not been altered ...
Wiring Simon XT To Telephone Line
The manual for the Simon XT suggests that there is a cord in the box that can be used to connect the Simon XT to your house phone jack. There is a cord but in reality most people have a standard RJ11 jack and not an RJ45 jack for their phone ...
Mobeye i110 Set Up FAQ
MOBEYE i110 Mobeye all-in-one GSM alarm system How to get started and other frequently asked questions Although we try to be complete in the manual, it could be that your Mobeye i110 system does not react in the way you want it to do. Please ...