Integrating Insteon with An Alarm System using an Insteon IOLinc 2450

Integrating Insteon with An Alarm System using an Insteon IOLinc 2450

The Insteon IOLinc can provide basic integration to an alarm system from DSC, GE, Visonic, etc.

Most alarm panels feature programmable outputs (PGM outputs) that can be set to trigger based on either a zone/sensor change, arm state, or alarm state.  By connecting these outputs to a relay like ELK-924, and the output of the relay to an IOLinc, an Insteon controller can 'see' this PGM change. 

The output of the IOLinc can be linked to an alarm zone to provide alarm activation.  Most alarms with wired inputs have a 'zone type' called 'key switch' or something similar.  This means that when the zone is activated, the alarm will arm and conversely when it's deactivated it will disarm.  By connecting the IOLinc output, to the 'key switch' zone, the alarm can be armed or disarmed by an Insteon controller.

Note that programming PGM outputs and Zone definitions requires the Installer programming code and if your alarm is monitored you will need to discuss this with your alarm or monitoring company prior to working on the alarm system.

    • Related Articles

    • Insteon Integration with a Security Alarm System

      Q: Is there an alarm system I can purchase which I can seemlessly connect with my insteon system?  A: There are several ways to integrate Insteon with an alarm system. The most basic integration would be using an Insteon 2450 IOLinc which can accept ...
    • Insteon Integration with a Security Alarm System

      Q: Is there an alarm system I can purchase which I can seemlessly connect with my insteon system?  A: There are several ways to integrate Insteon with an alarm system. The most basic integration would be using an Insteon 2450 IOLinc which can accept ...
    • Insteon Integration with a Security Alarm System

      Q: Is there an alarm system I can purchase which I can seemlessly connect with my insteon system?  A: There are several ways to integrate Insteon with an alarm system. The most basic integration would be using an Insteon 2450 IOLinc which can accept ...
    • EVL4 Universal Monitoring and Control of DSC Neo and Other Security Alarm Systems

      Since DSC Powerseries was discontinued and replaced by Neo alarm system panels, we have been asked if the EVL4 card is compatible for self monitoring or pro monitoring through the EyezOn or Connect2Go service and apps. As of writing the EVL4 is not ...
    • Integrating Elk M1 Gold with Insteon via ISY99 / ISY994

        It is possible for an Elk M1 Gold to 'see' Insteon status and also control Insteon devices through an ISY99 or ISY994 automation controller without having to purchase any additional software.  Using this method, one will program any Elk-Insteon ...