New Qolsys IQ4 Panel Won't Boot - Battery Issue - Troubleshooting

New Qolsys IQ4 Panel Won't Boot - Battery Issue - Troubleshooting

Qolsys has identified a batch(es) of IQ4 panels that may have discharged or severely discharged, or bad batteries.  If the new IQ4 panel won't boot initially please see the attached technical service bulletin on troubleshooting steps.

FIRST TRY:
  1. Check that the battery cable is properly inserted into the connector. 
  2. Insert the charging adaptor into the appropriate connector. 
  3. The LEDs should begin to flash red, indicating the panel is charging. The LEDs may remain flashing for up to 30 mins while the panel charges. The panel will boot once it receives sufficient charge.
THEN TRY:
  1. Unplug the battery and re-connect it
  2. Re-insert and then remove the charging adaptor 2-3 times, waiting 5 seconds between attempts, until the LED’s start to flash as described in Step 3 below.
  3. The LEDs will begin flashing red indicating the panel is receiving charge. The LEDs may remain flashing for up to 30 mins while the panel charges. The panel will fully boot once it receives sufficient charge.

If neither works and you purchased the panel from Aartech Canada, please open a support/returns ticket.
    • Related Articles

    • Neo Panel Firmware V1.9 Upgrade Nov 2023

      Due to a firmware issue, DSC Neo panels including HS2016, HS2032, HS2064, HS2128 running V1.38 need to be updated to V1.39 as soon as possible. This will be done using a PCLINK-USB cable and DLS5 software. The attached documents outline the upgrade ...
    • Troubleshooting Lutron Bridge Connection

      If you're experiencing difficulty installing and connecting your Lutron Caseta bridge, please double check these steps: https://support.lutron.com/us/en/product/casetawireless/article/bridge-connection/Smart-Bridge-Set-up-Troubleshooting Contents of ...
    • Uniview Waterproof RJ45 Boot and Installation Instructions for Outdoor Exposed Installations

      Uniview outdoor rated IP cameras come with a waterproof "boot" in the box. If the cable connection is exposed rather than enclosed in a sealed junction box or in the wall, this boot must be installed correctly to ensure water cannot infiltrate the ...
    • Foscam Expired Internet Explorer Certificate Issue

      A message from Foscam:   Recently we have received some feedback that the plug-in could not be installed on IE browser. The IE browser block the plug in for the Certificate of the plug-in is expired. This issue only happen when logging in the camera ...
    • Troubleshooting a Beeping or Chirping Smoke Detector or Carbon Monoxide Detector

      If your smoke detector or carbon monoxide detector is sounding an alarm, you need to take action immediately to check for smoke or in the case of a carbon monoxide alarm clear the building and call the fire department to check for dangerous CO ...