Following is a step by step guide to set up the Zeon Labs DSA22 Zwave Fob as a primary controller to control a Zwave device.  Zwave can have only ONE primary controller for each network.  If there is already another Primary controller (eg. Vera, Hometroller, another Remote) then these instructions will not work, follow the user manual to set up as a secondary controller instead.

  1. Open the remote, press the 'Include' (top left) button once. The green light on the remote should start flashing.  If it doesn't start flashing,  see below.
  2. Press the 'include' button on the Zwave device you are adding.  In the case of Evolve for example, you will 'double tap' the On button.  The green light should stop flashing.
  3. Press the 'include' button again to stop including devices.
  4. Use the 'push pin' to press the 'mode' button on the back of the remote.  The green light should flash once.
  5. Press and HOLD the button on the remote, that you want to CONTROL your Zwave device.  Keey Holding. Do not release until step
  6. Press the network button on the Zwave device (For evolve, double tap ON)
  7. Set the controlled device to the level you want (on, off, dimmed)
  8. Now let go of the remote's button
  9. Press the same remote button
  10. It should now be controlling your zwave device.

 

NOTE1:

If step one doesn't result in the the green light flashing on the remote, it's possible the remote was not in SETUP mode.  In this case, use the push pin device, to press the 'MODE' button on back of the fob.  The light should flash once.  Now try Step 1 again.  If this does not work, follow the user manual to RESET the fob and start again.

 

NOTE 2:

If the Fob flashes properly during include mode, but the Zwave responder won't add - with the Fob still in SETUP mode, press the REMOVE (top right) butotn on the Fob, the RED light should start flashing.  Press the network button on the responder device (for Evolve, double tap ON).  This will remove the device.  Then try step 1 again to include the device.

    • Related Articles

    • Aeotec / Aeon Labs Support

      Aeon Labs / Aeotec maintain a support site including a ticketing system for technical help, and a knowledgebase, found here: https://aeotec.freshdesk.com    
    • Procedure for converting DSC 6 digit serial numbers to 5 digit serial numbers

      The 1st digit of ESN number is also 1st digit of SN Open up calculator in Microsoft Windows Click on VIEW at top of calculator and select SCIENTIFIC (or PROGRAMMING in Vista or Win 7 Click on HEX button at top left of calculator Input the 2nd, 3rd ...
    • Powermax Programming Software

      Click Here to download the Visonic Powermax Remote Programming Software Link from our download section.
    • DSC DLS Programming Software

      DSC's DLS downloading & programming software allows local and remote programming of DSC PowerSeries and Neo security systems using Windows software. For professional installers please register with DSC to access DLS sofware and materials: ...
    • First Alert Zwave Smoke and Zwave Combo

      Q. Why dont you carry First Alert's zwave smoke and smoke/co sensors? 'Id like to purchase the zcombo or zsmoke (product codes). A. It's not approved for sale in Canada so we can't. They don't have any plans to release it here from our talks with ...