Replace 330L smoke detector

Replace 330L smoke detector

> My home has smoke alarm installed by builder in 1990. There are 3 alarms
> which I believed are connected together. The model is Dicon 330L which I
> believed is no longer available by searching the internet. And, they
> recommended to search your company's replacement product.

Hello,

Yes, the 330L was discontinued a long time ago and at this point all of your detectors are well beyond their expected life span and need to be replaced. You can consider using a combination of 9120BA smoke detectors and SC9120BA Smoke/CO combination detectors. You will need to replace both the mounting bracket(two screws) and the wiring harness/plug (connected by MAR connectors to your 120V wiring. The new detectors include both a mounting bracket and correct wiring plug.

You can find product here:
https://www.aartech.ca/9120ba-brk-ionization-smoke-detector-120v-battery-backup.html
https://www.aartech.ca/9120ba-brk-ionization-smoke-detector-120v-battery-backup.html

We have some additional information here:
https://www.aartech.ca/page/cos2010-sa360

 

    • Related Articles

    • Troubleshooting a Beeping or Chirping Smoke Detector or Carbon Monoxide Detector

      If your smoke detector or carbon monoxide detector is sounding an alarm, you need to take action immediately to check for smoke or in the case of a carbon monoxide alarm clear the building and call the fire department to check for dangerous CO ...
    • Add existing wired smoke detectors to a DSC alarm system

      We are often asked how to add smoke detectors to a DSC alarm system. First we need to point out that smoke detectors are a life safety product and so it's critical that you read and understand how the connection should work, and hire a pro if needed. ...
    • When Should I Replace My Smoke Detector

      Most smoke detectors have a 10 year warranty.  In addition, the ability of a smoke detector to function reliably after 10 years of service is diminished.  We recommend that smoke detectors are replaced AT LEAST every 10 years. However if they are not ...
    • Wiring / Connecting 2 Wire and 4 Wire Smoke Detectors to an Alarm System

      We are often asked how to connect low voltage smoke detectors to a wired alarm system.  First we need to point out that smoke detectors are a life safety product and so it's critical that you read and understand how the connection should work, and ...
    • If I replace my smoke detector do I need to replace the bracket and wires?

      In most cases, the mounting bracket and wires used to connect a smoke detector to the ceiling and power, are proprietary to the brand or model so you'll need to replace the mounting bracket and the wire harness (plug). The good news is that both are ...