In case you accidentally program the partition or other settings incorrectly in the keypad or you're having trouble getting wireless to work in an RFK series keypad, you can reset the keypad following this procedure:

*8 [INSTALLER CODE] 999 *

 

    • Related Articles

    • Enrolling Wireless Sensors on DSC Systems Using RFK5501 Keypad

      How to enroll wireless devices into a DSC alarm system using a PK5501 or RFK5501 keypad by manually entering the device ESN. Enter [ ✱ ][8][Installer Code][804].   01 for Zone 1 02 Zone 2 and so on Enter in 6 digit ESN number then hit # twice Enter ...
    • Reset EVL-4

      There is a reset pad on the EVL4 near the PCLINK connector. Use a screwdriver or tweezers to short the pads for 5 seconds or until it reboots.
    • Factory Reset SC1200

      Hold CLEAR until you see HOME CONTROL, then press 7 then 9 then ON then CLEAR. This will reset the PIN to 0000, but retain all other settings.
    • Factory Reset DSC PC1616 / PC1832 / PC1864

      If you have lost or forgotten your installer code for Powerseries (PC1616/PC1832/PC1864) and need to make changes to the system programming you will need to factory reset the panel which will remove/reset ALL programming and should also reset the ...
    • AC Power Indicator Is Not Lighting Up on DSC Keypad

      By default the AC status indicator does not light up on DSC keypads. There is an option in programming to turn it on if desired. The option is shown in the installation manual that comes with the keypad (not the system) but in brief: Enter ...