Misc
Setting Up Visonic PowerLinc Camera
Please follow the following steps to configure your power link with any of the Visonic IP Cameras. Visionic Powerlink Setup & IP cam The IP cam virtually had no setup required. Once you have the Powerlink working and setup correctly, as soon as you ...
Alternatives to X10 or Equipment Compatible with X10
X10's manufacturing division went out of business a few times in the last several years, and X10.com did the same in 2013 which means that X10 as it was known no longer exists The X10.com site is now owned by a company called Authinx Inc who is ...
Can't Change House/Unit code on KR19A Keychain Remote
X10 has been shipping two different versions of the KR19A. One uses the standard programming methods, and the 2nd uses different programming method outlined below. Otherwise both remotes function the same. To change the Housecode Press and hold the ...
Cannot Install Activehome Pro
In order to install Activehome Pro, the software would actually look to X10's servers for the current version and to activate the copy. Unfortunately X10 went out of business earlier in 2013 and as a result their servers were shut down and it is not ...
Factory Reset SC1200
Hold CLEAR until you see HOME CONTROL, then press 7 then 9 then ON then CLEAR. This will reset the PIN to 0000, but retain all other settings.
WS467 Not Turning On
WS467 appears to be not working? The newer versions of WS467 X10 switches now support local dimming, fade-on/fade-off and resume level, which means that when you press the switch it will gradually ramp instead of turning on to 100% power. If you ...
X-10 or Insteon Devices Not Communicating
Powerline (eg. X10, Insteon, UPB) automation signals travel along the household power wiring. There are two main issues that can affect performance. One is that your house electrical system is split in to 2 phases at the breaker panel. The other ...
120V - 240V (Baseboard) Heating with Insteon, WIFI, Zwave Thermostats
At time of writing, there is no such thing as a 120V or 240V thermostat from any automation vendors - Insteon, Zwave, etc as the demand isn't high enough. But what you do is use a low voltage automated thermostat, and use a thermostat relay on the ...
Are there any automated light switches that are available that dont require the neutral wire?
> Are there any light switches that are available that dont require the neutral wire. > Most automated light dimmer switches, and all on/off switches require connection for hot and neutral to provide power to the switch's circuitry (the switch's ...
Evolve LFM-20 Controlling 120V Load
The LFM-20 is powered by 120VAC (house voltage), and has an isolated relay. This means the 2 blue wires, the relay output, are not powered normally. They can be used to switch anything within the load rating from dry contact, to low voltage and ...
Yale lock is locking backwards
The Yale Real Living lock will automatically determine whether it will function as a right or left-handed lock. (The "hand" or "handing" of the lock, is determined by the side of the entry door that the hinges are on when standing outside the door). ...
Dicon American Sensors SA360 Replacement
Dicon (American Sensors) SA360 has been discontinued with no direct wire replacement. You can replace your SA360 (in Canada) with 9120A or 9120BA from BRK which is made by the same factory and is cross listed as compatible.. You should replace all ...