            DSC Alarm Without Telephone Connection

            If you will not be connecting your DSC alarm system to a telephone line, you need to ensure that it understands this, since by default it expects a phone condition and will give a trouble warning if the panel is not connected to a working phone line.

            Enter Installer Programming
            *85555  (default installer code is 5555)

            You should see ENTER SECTION or the PROGRAM light will flash on an LED only keypad

            [380] 1st Communicator Options

            Opt 1 ON if you want the alarm to call you. 
            Opt 1 OFF if no phone line or reporting required

            [015] 3rd System Option Code
            Opt 7 - TLM (telephone line monitoring) - Turn this option OFF if the alarm is not connected to phone line to avoid a trouble condition.

            When in programming, the # key exists the section, ## exits programming
            Armed Light On  - Panel waiting for 3 digit section number
            Read Light On - Panel waiting for data
            Ready Light Flashing - Panel waiting for HEX data