Enrolling DSC Wireless Sensors on RFK5500

Enrolling DSC Wireless Sensors on RFK5500

 

Note: Default installer code is 5555

1. Enter [ ✱ ][8][Installer Code][898]. The LCD displays the following: “Wireless Enrollment Mode.”
2. Place the wireless device in the desired location.
3. Activate the device as described in the associated installation sheet. The electronic serial number (ESN) is displayed.
4. Press [ ✱ ] to confirm the ESN. If the serial number is incorrect, press [#] to discard it, and repeat this step. After successful confirmation of
the serial number, the system prompts for the zone number. The next available zone is displayed.
5. Enter a zone number (01-64) then press [ ✱ ] to accept. The next available zone is preloaded.

NOTE: Only one device may be enrolled in each zone. If a zone already has a device enrolled, press [*] to overwrite the zone or [#] to enter
another zone number.
6. After successful entry of the zone number, the system prompts for the zone type. (The recommended zone type is displayed). Press [ ✱ ] to
accept the zone type or enter:

Device Type                                   Zone Definition
2 Door/Window Contact                 [01] Delay 1
3 PIR or Glassbreak                        [05] Interior, Stay-Away
4 Smoke Detector                          [88] Standard 24 Hr Fire (Wireless)
5 Pendant                                     [16] 24 Hour Panic
8 CO Detector                               [81] 24 Hour CO Detection