Leviton VRI06 2 wire Dimmer Stopped woking

Leviton VRI06 2 wire Dimmer Stopped woking

If your Leviton VRI06 2 wire dimmer stops working, first check the breaker to ensure there is power to your circuit and it hasn't tripped.  Next check the light bulb to ensure it is not blown.  2 wire dimmers work by passing a little current through the filament of the incandescent light bulb.  This is why they are not compatible with LED or CFL bulbs.  If the light bulb burns out, the filament is broken and the circuit cannot be completed, so the switch will also stop working.

    • Related Articles

    • Insteon Dimmer Compatibility with LED Lights

      LED lights are great for saving energy compared to their older incandescent counterparts.  However, being able to dim LED lights has proven to be challenging.  Where incandescent lights had nothing more than a filament inside (piece of wire that ...
    • Insteon 2474 2 Wire Dimmer Lost Power

      If your Insteon 2474 2 wire dimmer stops working, first check the breaker to ensure there is power to your circuit and it hasn't tripped.  Next check the light bulb to ensure it is not blown.  2 wire dimmers work by passing a little current through ...
    • Zwave Dimmers and Switches Without Neutral Wire

      Most Zwave dimmers and ALL Zwave on/off switches require a neutral connection (learn more).  This is because Zwave products need a small amount of power to operate and this comes from the hot & neutral wires coming to the switch.  If you have ...
    • ZWave Dimmer for LED Lights

        If we are talking about screw in replacement LED bulbs available from a big box store, there is no guarantee from any vendor of any dimmer because there are too many variables. Certainly it has to be certified for dimming but they are not all ...
    • Leviton Contacts

      Leviton Contacts Contact US: Mon-Fri 6:30 AM-5:00 PM Pacific Time (Toll-free) USA: 1-800-824-3005 Mon.-Fri. 8:30AM to 7:00PM ET Canada: 1-800-405-5320 Mon.-Thurs. 8:00AM to 5:00PM ET Fri. 8:00AM to 4:30PM ET ...