Programming Zone Labels on DSC PK5500 Alpha Keypads

Programming Zone Labels on DSC PK5500 Alpha Keypads

The programming instructions for labelling zones on a PK5500 keypad are found in the keypad manual (not the main installation manual). They are a bit vague, so to summarize the sequence would be:

 

*8
Installer's Code
*
001  (for zone one, 002 for zone 2 and so on, must be 3 digits)
XXXXXXX Label XXXXXXXX  (see below for instructions to change the label)
*
* (save)
Then the next section. 
When done, use ## to exit programming

To change the label, use the arrow keys to move the underline to the character that needs to be changed then use the numbers 1-9 on the keypad to choose the number.  Each time you press the number you change the leter as outlined below.

[1] A,B,C,1[2] D,E,F,2
[3] G,H,I,3
[4] J,K,L,4
[5] M,N,O,5
[6] P,Q,R,6
[7] S,T,U,7
[8] V,W,X,8
[9] Y,Z,9,0

 

    • Related Articles

    • Programming Zone Labels on PowerSeries with IT100 Connected

      If you install a DSC IT100 and cannot program zone labels on PowerSeries, disconnect the IT100 from the panel and try again.  It may not allow zone label programming while the IT100 is connected.
    • Procedure for converting DSC 6 digit serial numbers to 5 digit serial numbers

      The 1st digit of ESN number is also 1st digit of SN Open up calculator in Microsoft Windows Click on VIEW at top of calculator and select SCIENTIFIC (or PROGRAMMING in Vista or Win 7 Click on HEX button at top left of calculator Input the 2nd, 3rd ...
    • PK5500 V1.32

      PowerSeries panels v4.62 not clearing the "Fire Alarm <> bell silence" message     PC1832 v4.62 and RF5500 v1.32 and PK5500 v1.34 not able to clear the message following: Enter code to acknowledge the alarm/reset with *72/ secure the zone.     1) ...
    • Quick Guide For Programming DSC Powerseries Alarms

      Quick Guide To Programming DSC Powerseries Alarm Panels The following guide outlines the basic programming required when installing a DSC Powerseries Alarm System. This is a very short version designed to get most alarms up and running quickly.  For ...
    • Connect 120V wired smoke detectors to security alarm system like DSC, Vista, Concord

      We are often asked how to add 120V wired smoke detectors to a low voltage security alarm system like DSC, Vista, Concord or Elk. First we need to point out that smoke detectors are a life safety product and so it's critical that you read and ...