Wiring Simon XT To Telephone Line

Wiring Simon XT To Telephone Line

The manual for the Simon XT suggests that there is a cord in the box that can be used to connect the Simon XT to your house phone jack.  There is a cord but in reality most people have a standard RJ11 jack and not an RJ45 jack for their phone connection inside the home. 

That being said, it is not recommended to connect the Simon XT to a single telephone jack unless it is the ONLY phone being used in the home, because it does not provide "line seizure'.  Line seizure means that when the alarm needs to call out in an emergency, it can actually disconnect all of the other house phones, wait for a dial tone, then call out to you or the number(s) you have programmed.

So what they provide in the box is an RJ31X (beige box) and a cord that has bigger (RJ45) ends on it.

Connect the included cord from the RJ31X jack, to the Simon XT LINE connector.

If you don't care about line seizure and want to plug the Simon XT in to a regular phone jack, run down to your local dollar store or electronics shop and pick up a standard RJ11 telephone cord.  You may have one kicking around from a phone you don't use any more.  Cut one end off and look for the red and green wires inside.  You will find that you can (carefully) plug it in to the big LINE jack on the Simon XT and it will work fine.

If you want to have proper line seizure, use a 4 conductor wire to run from where the phone line enters the home BEFORE it goes to any telephones, and run your wire to the RJ31X jack included with the Simon XT and following the wiring shown on page 26 of the Simon XT Installer Manual online.

    • Related Articles

    • GE Simon XT Self Monitoring Set-Up

      Ensure that phone line is connected to the larger jack on back of the Simon XT Ensure that the phone service type is not VOIP, which may not be compatible with the Simon XT dialer Enter in the appropriate telephone number(s) to call including area ...
    • RJ31X / CA38X Telephone Wiring Information

      Your alarm system likely came with a cable & jack set for connecting your alarm system to the telephone system in your home.  Particularly if you are having your security system professionally monitored, it's critical that the alarm can ALWAYS get a ...
    • GE Interlogix Simon XT V2 Installer and User Manual

      Simon XT Installation and Programming manual, and user manuals. For V2 versions of panel shipping since Sept 2010
    • Adding a wired siren to Simon XT and Xti

      To use a wired siren with a Simon XT or XTi system: Negative wire from the siren to the HW1- on the panel. Positive wire to the + HW 1&2 DC out. You will also need to program the panel to tell it you have a siren tied in to the panel:     Go to ...
    • Wiring / Connecting 2 Wire and 4 Wire Smoke Detectors to an Alarm System

      We are often asked how to connect low voltage smoke detectors to a wired alarm system.  First we need to point out that smoke detectors are a life safety product and so it's critical that you read and understand how the connection should work, and ...