Can't Program X10 Address In To SwitchLinc Insteon Device
Most Insteon devices can accept an X10 code and can be controlled by an X10 wired transmitter. However Insteon devices do not come pre-set with any X10 address. You must program one. Here's how:
- Put the Insteon device in to Link Mode (press set button and hold for 3-4 seconds, or press and hold dimmer for 10 seconds, see device instructions)
- If you have an X10 Maxi controller you can just press the unit button on the device 1-3 times
- On other controllers, for the unit code you wish to set, send on-off-on instead
Related Articles
Can't Program X10 Address In To SwitchLinc Insteon Device
Most Insteon devices can accept an X10 code and can be controlled by an X10 wired transmitter. However Insteon devices do not come pre-set with any X10 address. You must program one. Here's how: Put the Insteon device in to Link Mode (press set ...
Insteon Warranty
At time of writing, we haven't had any communication whatsoever from Insteon, Smarthome or SmartLabs in some time but according to the smart home community it's likely that Insteon may have shut down. The Insteon Hub servers and Insteon Forums have ...
Insteon i3 Device Support with Insteon and UDI ISY994 / EISY Hubs
Insteon is now shipping i3 devices. These i3 devices can be used with other Insteon devices or with smart hubs. The Insteon Hub supports the i3 devices natively. Universal Devices ISY994 hubs are end of life and no new features or devices support are ...
Insteon Hub Not Working - Red Light - Won't Connect
The Insteon Hub requires a cloud connection Insteon's servers in order to function. Unfortunately it appears that the Insteon Servers that power the Insteon Hub have gone offline. Without the cloud connection you are likely seeing a red light on ...
X-10 or Insteon Devices Not Communicating
Powerline (eg. X10, Insteon, UPB) automation signals travel along the household power wiring. There are two main issues that can affect performance. One is that your house electrical system is split in to 2 phases at the breaker panel. The other ...