DSC
DSC Meridian MN140 or MN140C Smoke Detector Alternative Replacement
The DSC 'Meridian' MN140 series smoke detector was a 4 wire smoke detector that was discontinued many years ago. DSC no longer makes wired smoke detectors so another brand will need to be used to replace a failed unit. The System Sensor 2012JA is one ...
Neo Panel Firmware V1.9 Upgrade Nov 2023
Due to a firmware issue, DSC Neo panels including HS2016, HS2032, HS2064, HS2128 running V1.38 need to be updated to V1.39 as soon as possible. This will be done using a PCLINK-USB cable and DLS5 software. The attached documents outline the upgrade ...
DSC Neo HS2016 HS2032 HS2064 Manual
See attached files for DSC Neo Installation manual and reference manual for HS2016 H2032 HS2064 alarm systems.
Programming Zone Labels on PowerSeries with IT100 Connected
If you install a DSC IT100 and cannot program zone labels on PowerSeries, disconnect the IT100 from the panel and try again. It may not allow zone label programming while the IT100 is connected.
Remove fire, medical and panic function on a DSC keypad.
*8 Installer code press * press 074 If 1,2 and 3 are showing then press 1 then 2 then 3 to make them disapper ## to exit
PK5500 V1.32
PowerSeries panels v4.62 not clearing the "Fire Alarm <> bell silence" message PC1832 v4.62 and RF5500 v1.32 and PK5500 v1.34 not able to clear the message following: Enter code to acknowledge the alarm/reset with *72/ secure the zone. 1) ...
PC1616/PC1832/PC1864 Install guide
Download may be found here
AC Power Indicator Is Not Lighting Up on DSC Keypad
By default the AC status indicator does not light up on DSC keypads. There is an option in programming to turn it on if desired. The option is shown in the installation manual that comes with the keypad (not the system) but in brief: Enter ...
Changing DSC Alarm System Entry and Exit Delays
To adjust DSC alarm system entry and exit delays: *8 (installer code) type in 005 for section 5 then 01 for partition 1 then 001 for entry then 001 for exit Then ## to exit 1 minute is the lowest delay.
DSC Alarm Cannot Communicate With DLS Software
First please triple check that the PCLINK serial board is plugged in correctly as it is possible to insert it incorrectly or off by a pin. Generally speaking the issue here is that the customer/installer is using a DSC serial interface while today's ...
DSC Alarm Residential Dial Keeps Calling Ends In Communication Trouble
Symptom: DSC Alarm panel is set to residential dial to a private phone or cellular phone. When the system calls, no tone is heard and it keeps calling back. Eventually it ends and the panel displays a communication trouble error. Solution: Set ...
DSC Alarm Without Telephone Connection
If you will not be connecting your DSC alarm system to a telephone line, you need to ensure that it understands this, since by default it expects a phone condition and will give a trouble warning if the panel is not connected to a working phone line. ...
DSC DLS Programming Software
DSC's DLS downloading & programming software allows local and remote programming of DSC PowerSeries and Neo security systems using Windows software. For professional installers please register with DSC to access DLS sofware and materials: ...
DSC End User Manuals / Operating Guides
Home and Business owners looking for documentation or user manuals for DSC equipment or help identifying their equipment, can find them at the DSC end user portal found here: http://www.dsc.com/index.php?n=enduser Installation and programming manuals ...
DSC PC1555MX Installation Manual
DSC PC1555MX Installation manual
DSC PK5501 / RFK5501 Show Open Zones
If you wish to have the DSC PK5501 / RFK5501 keypad show open zones automatically, turn on Option 8 in section 076 of Keypad Programming. *8 Installer's Code * 076 8 ##
DSC Powerseries Comparison and Guide To Choosing a DSC Alarm
If you'ved decided on DSC, this guide will help you determine what you need. There are three main boards that are the 'brains' of the system. PC1616, PC1832, PC1864 For more details please see the attached DSC Alarm Comparison, showing PC1616, ...
DSC Powerseries PC1616/PC1832/PC1864 EOL Resistors vs Closed Loop Programming
By default, DSC Powerseries wired panels are expecting each zone to have EOL resistors installed. If you are not going to use EOL resitors, you will need to turn Section 013 Option 1 to ON otherwise your zones will show open. After you exit ...
DSC Powerseries Residential Dial On Alarm
DSC Powerseries alarms can call out using a landline telephone connection, to an ouside telephone or cell# to alert the user of an alarm. The indication is very basic (beeping and a siren sound) but it will indicate a situation requiring the owner's ...
DSC Powerseries/Alexor Residential Dial (Self Monitoring) Programming
If you wish to have your DSC Alexor alarm system use residential dial (self monitoring) be sure to set the following sections appropriately: Some of these are already defaulted that way but better to check them to ensure they have not been altered ...
DSC RM-1 Wiring
As of the time of writing (Aug 27th 2010) the RM-1 wiring is as follows: Black - negative coil Red - positive coil White - common Yellow - normally closed Green - Normally Open
Enrolling DSC Wireless Sensors on RFK5500
Note: Default installer code is 5555 1. Enter [ ✱ ][8][Installer Code][898]. The LCD displays the following: “Wireless Enrollment Mode.” 2. Place the wireless device in the desired location. 3. Activate the device as described in the associated ...
Enrolling Wireless Key Fobs To DSC RFK5500/RFK5501 Keypads
Wireless keyfobs need to be enrolled in slots 41 through 56 with the first key in 41, second key in 42, etc. So to register the first key fob: *8 Installer's Code 804 41 XXXXXX (the Electronic Serial Number of fob #1) ## If the fob does not ...
Enrolling Wireless Sensors on DSC Systems Using RFK5501 Keypad
How to enroll wireless devices into a DSC alarm system using a PK5501 or RFK5501 keypad by manually entering the device ESN. Enter [ ✱ ][8][Installer Code][804]. 01 for Zone 1 02 Zone 2 and so on Enter in 6 digit ESN number then hit # twice Enter ...
Entering Hex Digits on DSC System
Some device ESN contain LETTERS. In this case, use the following sequence to represent that letter HEX [A] enter [*][1][*] HEX [B] enter [*][2][*] HEX [C] enter [*][3][*] HEX [D] enter [*][4][*] HEX [E] enter [*][5][*] HEX [F] enter [*][6][*]
Factory Reset DSC PC1616 / PC1832 / PC1864
If you have lost or forgotten your installer code for Powerseries (PC1616/PC1832/PC1864) and need to make changes to the system programming you will need to factory reset the panel which will remove/reset ALL programming and should also reset the ...
Problem with DSC Keypad Power or Devices Won't Power
Keep in mind that DSC Powerseries wired alarms can provide up to 700mA current to connected devices. While this is typically sufficient for multiple keypads and zone expanders, it is important to make sure this limit is not exceeded. The newer LCD ...
Programming Zone Labels on DSC PK5500 Alpha Keypads
The programming instructions for labelling zones on a PK5500 keypad are found in the keypad manual (not the main installation manual). They are a bit vague, so to summarize the sequence would be: *8 Installer's Code * 001 (for zone one, 002 for ...
Quick Guide For Programming DSC Powerseries Alarms
Quick Guide To Programming DSC Powerseries Alarm Panels The following guide outlines the basic programming required when installing a DSC Powerseries Alarm System. This is a very short version designed to get most alarms up and running quickly. For ...
Reset PK5500/PK5501 and RFK5500/RFK5501 Keypad
In case you accidentally program the partition or other settings incorrectly in the keypad or you're having trouble getting wireless to work in an RFK series keypad, you can reset the keypad following this procedure: *8 [INSTALLER CODE] 999 *
Setting The Time On DSC Alarm Systems
Please see the pdf attachment listed below, for instructions to set the time on various DSC alarm panels. For the current Powerseries PC1616/PC1832/PC1864, Alexor and 9047 alarm systems, follow these instructions: Step 1 – Enter time/date programming ...
The wireless part of RFK5501 is not being registered by the panel - never displayed 17 in section 903
If there is nothing programmed in your wireless receiver, then you will not see 17 in section 903. Go to 804 and program at least one wireless device and then you will see 17 in section 903.
What Does The Yellow Trouble Light On My DSC Keypad Mean and How Can I Stop The Beeping?
What Does The Yellow Trouble Light On My DSC Keypad Mean? The yellow trouble light indicates a system problem of some sort. To find out the cause of the trouble light, press *2 on your keypad. On a LCD keypad: 1 is a system problem, press 1 again ...
Wiring DSC SS102 Shock Sensor
The manual can be a bit confusing.. for basic operation: Terminal 1 - 12VDC Power + Terminal 2 Power Negative Terminals 3 and 4 are NC to zone input
WTK5504, WTK5504P Won't Enrol
If you're having issues enrolling a new WTK5504 or WTK5504P keypad in your DSC powerseries system, try a manual enrol: On the keypad, after a power cycle, press both the minutes, and the seconds on the keypad at the same time. This will force a ...
Connect2Go DLS2Go Server Setup
Connect2Go DLS2Go Server Setup This is intended for Pro Installers using the Connect2Go Portal and EVL4-CG Cards Provided as a courtesy. For technical support regarding DLS downloading please contact Eyezon / Connect2Go Directly Aartech Canada will ...
EVL4 Stuck In Boot Loop
There is a specific firmware version of EVL4 that can cause a boot loop *IF* the card is set for a static IP *and* has not yet connected to the eyezon portal for a firmware update. It is always best to register the card on the Eyezon portal so it ...
Reset EVL-4
There is a reset pad on the EVL4 near the PCLINK connector. Use a screwdriver or tweezers to short the pads for 5 seconds or until it reboots.
Connect 120V wired smoke detectors to security alarm system like DSC, Vista, Concord
We are often asked how to add 120V wired smoke detectors to a low voltage security alarm system like DSC, Vista, Concord or Elk. First we need to point out that smoke detectors are a life safety product and so it's critical that you read and ...
Procedure for converting DSC 6 digit serial numbers to 5 digit serial numbers
The 1st digit of ESN number is also 1st digit of SN Open up calculator in Microsoft Windows Click on VIEW at top of calculator and select SCIENTIFIC (or PROGRAMMING in Vista or Win 7 Click on HEX button at top left of calculator Input the 2nd, 3rd ...